Part family guide

American Standard Pressure-Balance Service Parts

American Standard services multiple pressure-balance valve generations with different cartridges and balancing units; the exact rough-in and parts diagram determine which assembly applies.

Measure before purchase

Direct answer

M952100-0070A is documented as a pressure-balancing unit for R110, R120, R115, and R125 rough-in valves. American Standard lists 023529-0070A separately as a volume-and-temperature control pressure-balance valve cartridge. Identify the rough-in and component function before selecting either part.

Fit facts

What identifies this match

Use these details together. One matching feature does not establish compatibility.

M952100 application
R110, R120, R115, and R125 rough-in valves
M952100 function
Pressure-balancing unit with diaphragm and integrated check valves
023529 classification
Volume and temperature control pressure-balance valve cartridge
Application unit
Exact rough-in or valve model
Critical distinction
Balancing unit versus control cartridge
Selection authority
Current manufacturer product page and model parts sheet

One function does not mean one part

Pressure-balance shower valves reduce sudden temperature changes caused by shifts in supply pressure, but American Standard has used different internal architectures and service assemblies. A common purpose and branded trim do not establish interchangeability.

Start with the rough-in or valve model. The service drawing must identify whether the repair calls for a complete control cartridge, a separate pressure-balancing unit, or another assembly.

M952100-0070A in context

American Standard's current page says M952100-0070A maintains output as hot- and cold-supply pressures change. It names R110, R120, R115, and R125 rough-in valves and describes a diaphragm system with integrated check valves.

That is a narrower, testable application. Do not broaden it to every American Standard pressure-balance valve or rename it as a generic Ceramix cartridge.

023529-0070A is a separate record

The 023529 product page uses the title Volume and Temperature Control Pressure Balance Valve Cartridge. It is a distinct service record with different imagery and identifiers.

Number similarity, pressure-balance wording, or a seller's combined search page does not prove that 023529 and M952100 can replace one another.

Inspect the complete assembly

With water safely isolated, compare the original part's stem, limit-stop arrangement, locating tabs, diaphragm or spool features, seals, ports, and retention. Preserve every adapter and note which component the model diagram calls out.

If the official model record and installed part disagree, stop and resolve the valve identity with American Standard support before ordering.

Questions

Before you remove or replace the part

Which rough-ins are listed for M952100-0070A?

American Standard's current page names R110, R120, R115, and R125 rough-in valves.

Is M952100-0070A the same component as 023529-0070A?

No equivalence is established. Their current manufacturer pages classify and present them as separate service parts.

What proves a replacement relationship?

A current official model parts sheet or manufacturer cross-reference that explicitly maps the installed valve to the service part.